Get_Baseline/Result/Prechange_attenuation_HA_QTSC.txt

1 line
5.6 KiB
Plaintext
Raw Permalink Normal View History

2025-11-13 20:18:23 +07:00
haudt3@QTSC_INT_FPT_MX80> show interfaces diagnostics optics xe-0/0/0 Physical interface: xe-0/0/0 Laser bias current : 37.200 mA Laser output power : 0.6340 mW / -1.98 dBm Module temperature : 40 degrees C / 103 degrees F Laser rx power : 0.2327 mW / -6.33 dBm Laser bias current high alarm : Off Laser bias current low alarm : Off Laser bias current high warning : Off Laser bias current low warning : Off Laser output power high alarm : Off Laser output power low alarm : Off Laser output power high warning : Off Laser output power low warning : Off Module temperature high alarm : Off Module temperature low alarm : Off Module temperature high warning : Off Module temperature low warning : Off Laser rx power high alarm : Off Laser rx power low alarm : Off Laser rx power high warning : Off Laser rx power low warning : Off Module not ready alarm : Off Module power down alarm : Off Tx data not ready alarm : Off Tx not ready alarm : Off Tx laser fault alarm : Off Tx CDR loss of lock alarm : Off Rx not ready alarm : Off Rx loss of signal alarm : Off Rx CDR loss of lock alarm : Off Laser bias current high alarm threshold : 80.000 mA Laser bias current low alarm threshold : 15.000 mA Laser bias current high warning threshold : 75.000 mA Laser bias current low warning threshold : 20.000 mA Laser output power high alarm threshold : 1.4120 mW / 1.50 dBm Laser output power low alarm threshold : 0.1990 mW / -7.01 dBm Laser output power high warning threshold : 1.2580 mW / 1.00 dBm Laser output power low warning threshold : 0.2510 mW / -6.00 dBm Module temperature high alarm threshold : 83 degrees C / 181 degrees F Module temperature low alarm threshold : -13 degrees C / 9 degrees F Module temperature high warning threshold : 80 degrees C / 176 degrees F Module temperature low warning threshold : -10 degrees C / 14 degrees F Laser rx power high alarm threshold : 1.7783 mW / 2.50 dBm Laser rx power low alarm threshold : 0.0100 mW / -20.00 dBm Laser rx power high warning threshold : 1.5849 mW / 2.00 dBm Laser rx power low warning threshold : 0.0158 mW / -18.01 dBm haudt3@QTSC_INT_FPT_MX80> haudt3@QTSC_INT_EDGE_MX80_02> show interfaces diagnostics optics xe-0/0/2 Physical interface: xe-0/0/2 Laser bias current : 73.515 mA Laser output power : 1.2700 mW / 1.04 dBm Module temperature : 33 degrees C / 91 degrees F Laser rx power : 0.2209 mW / -6.56 dBm Laser bias current high alarm : Off Laser bias current low alarm : Off Laser bias current high warning : Off Laser bias current low warning : Off Laser output power high alarm : Off Laser output power low alarm : Off Laser output power high warning : Off Laser output power low warning : Off Module temperature high alarm : Off Module temperature low alarm : Off Module temperature high warning : Off Module temperature low warning : Off Laser rx power high alarm : Off Laser rx power low alarm : Off Laser rx power high warning : Off Laser rx power low warning : Off Module not ready